Thermographic camera

A thermographic camera or infrared camera is a device that forms an image using infrared radiation, similar to a common camera that forms an image using visible light. Instead of the 450–750 nanometer range of the visible light camera, infrared cameras operate in wavelengths as long as 14,000 nm (14 µm).

Contents

History

In 1929, Hungarian physicist Kálmán Tihanyi invented the first infrared-sensitive (night vision) electronic television camera for anti-aircraft defense in Britain.[1][2] The first conventional IR camera, the "Evaporograph", was declassified around 1956.[3]

Theory of operation

Infrared energy is just one part of the electromagnetic spectrum that encompasses radiation from gamma rays, x-rays, ultra violet, a thin region of visible light, infrared, terahertz waves, microwaves, and radio waves. These are all related and differentiated in the length of their wave (wavelength). All objects emit a certain amount of black body radiation as a function of their temperatures. Generally speaking, the higher an object's temperature is, the more infrared radiation is emitted as black-body radiation. A special camera can detect this radiation in a way similar to an ordinary camera does visible light. It works even in total darkness because ambient light level does not matter. This makes it useful for rescue operations in smoke-filled buildings and underground.

Images from infrared cameras tend to have a single color channel because the cameras generally use a sensor that does not distinguish different wavelengths of infrared radiation. Color cameras require a more complex construction to differentiate wavelength and color has less meaning outside of the normal visible spectrum because the differing wavelengths do not map uniformly into the system of color vision used by humans. Sometimes these monochromatic images are displayed in pseudo-color, where changes in color are used rather than changes in intensity to display changes in the signal. This is useful because although humans have much greater dynamic range in intensity detection than color overall, the ability to see fine intensity differences in bright areas is fairly limited. This technique is called density slicing.

For use in temperature measurement the brightest (warmest) parts of the image are customarily colored white, intermediate temperatures reds and yellows, and the dimmest (coolest) parts blue. A scale should be shown next to a false color image to relate colors to temperatures. Their resolution is considerably lower than of optical cameras, mostly only 160x120 or 320x240 pixels. Thermographic cameras are much more expensive than their visible-spectrum counterparts, and higher-end models are often deemed as dual-use and export-restricted.

In uncooled detectors the temperature differences at the sensor pixels are minute; a 1 °C difference at the scene induces just a 0.03 °C difference at the sensor. The pixel response time is also fairly slow, at the range of tens of milliseconds.

Thermal imaging photography finds many other uses. For example, firefighters use it to see through smoke, find persons, and localize hotspots of fires. With thermal imaging, power line maintenance technicians locate overheating joints and parts, a telltale sign of their failure, to eliminate potential hazards. Where thermal insulation becomes faulty, building construction technicians can see heat leaks to improve the efficiencies of cooling or heating air-conditioning. Thermal imaging cameras are also installed in some luxury cars to aid the driver, the first being the 2000 Cadillac DeVille. Some physiological activities, particularly responses, in human beings and other warm-blooded animals can also be monitored with thermographic imaging. Cooled infrared cameras can also be found at most major astronomy research telescopes.

Types

Thermographic cameras can be broadly divided into two types: those with cooled infrared image detectors and those with uncooled detectors.

Cooled infrared detectors

Cooled detectors are typically contained in a vacuum-sealed case or Dewar and cryogenically cooled. The cooling is necessary for the operation of the semiconductor materials used. Typical operating temperatures range from 4 K to just below room temperature, depending on the detector technology. Most modern cooled detectors operate in the 60 K to 100 K range, depending on type and performance level. Without cooling, these sensors (which detect and convert light in much the same way as common digital cameras, but are made of different materials) would be 'blinded' or flooded by their own radiation. The drawbacks of cooled infrared cameras are that they are expensive both to produce and to run. Cooling is power-hungry and time-consuming. The camera may need several minutes to cool down before it can begin working. The most commonly used cooling systems are rotary Stirling engine cryocoolers. Although the cooling apparatus is comparatively bulky and expensive, cooled infrared cameras provide superior image quality compared to uncooled ones. Additionally, the greater sensitivity of cooled cameras also allow the use of higher F-number lenses, making high performance long focal length lenses both smaller and cheaper for cooled detectors. An alternative to Stirling engine coolers is to use gases bottled at high pressure, nitrogen being a common choice. The pressurised gas is expanded via a micro-sized orifice and passed over a miniature heat exchanger resulting in regenerative cooling via the Joule–Thomson effect. For such systems the supply of pressurized gas is a logistical concern for field use.

Materials used for cooled infrared detection include photodetectors based on a wide range of narrow gap semiconductors including:

Infrared photodetectors can be created with structures of high band gap semiconductors such as in Quantum well infrared photodetectors.

A number of superconducting and non-superconducting cooled bolometer technologies exist.

In principle, superconducting tunneling junction devices could be used as infrared sensors because of their very narrow gap. Small arrays have been demonstrated. Their wide range use is difficult because their high sensitivity requires careful shielding from the background radiation.

Superconducting detectors offer extreme sensitivity, with some able to register individual photons. For example ESA's Superconducting camera (SCAM). However, they are not in regular use outside of scientific research.

Uncooled infrared detectors

Uncooled thermal cameras use a sensor operating at ambient temperature, or a sensor stabilized at a temperature close to ambient using small temperature control elements. Modern uncooled detectors all use sensors that work by the change of resistance, voltage or current when heated by infrared radiation. These changes are then measured and compared to the values at the operating temperature of the sensor. Uncooled infrared sensors can be stabilized to an operating temperature to reduce image noise, but they are not cooled to low temperatures and do not require bulky, expensive cryogenic coolers. This makes infrared cameras smaller and less costly. However, their resolution and image quality tend to be lower than cooled detectors. This is due to difference in their fabrication processes, limited by currently available technology.

Uncooled detectors are mostly based on pyroelectric and ferroelectric materials [1] or microbolometer technology. The material are used to form pixels with highly temperature-dependent properties, which are thermally insulated from the environment and read electronically.

Ferroelectric detectors operate close to phase transition temperature of the sensor material; the pixel temperature is read as the highly temperature-dependent polarization charge. The achieved NETD of ferroelectric detectors with f/1 optics and 320x240 sensors is 70-80 mK. A possible sensor assembly consists of barium strontium titanate bump-bonded by polyimide thermally insulated connection.

Silicon microbolometers can reach NETD down to 20 mK. They consist of a thin film vanadium(V) oxide sensing element suspended on silicon nitride bridge above the silicon-based scanning electronics. The electric resistance of the sensing element is measured once per frame.

Current improvements of uncooled focal plane arrays (UFPA) are focused primarily on higher sensitivity and pixel density.

Some of the materials used for the sensor arrays are e.g.: [2]

Applications

Originally developed for military use during the Korean War, thermographic cameras have slowly migrated into other fields as varied as medicine and archeology. More recently, the lowering of prices have helped fuel the adoption of infrared viewing technology. Advanced optics and sophisticated software interfaces continue to enhance the versatility of IR cameras.

Ghost Hunting

Infrared cameras have become a staple of ghost hunting investigations. Some episodes of Ghost Hunters and other paranormal programs show the team members using the camera to create false positive readings that amateur ghost hunters mistake for ghostly activity. Author and Investigator Benjamin Radford discusses how easily heat left by a body can be picked up by a infrared camera minutes after the person has moved from the spot, fooling ghost hunters into thinking they have just found evidence of a ghost.[4][5]

Specifications

Some specification parameters of an infrared camera system are:

References

  1. ^ http://www.hungarianhistory.com/lib/sipka.doc
  2. ^ http://www.ctie.monash.edu.au/hargrave/tihanyi.html
  3. ^ Mandell, Melvin. "Infrared: Jack of all Trades". Popular Electronics 1958 January.
  4. ^ Radford, Benjamin (November/December 2010). "Infrared Cameras and Ghost Hunting". Skeptical Inquirer (Committee for Skeptical Inquiry) 34 (5): 26. 
  5. ^ Radford, Benjamin (November/December 2010). "Ghost-Hunting Mistakes: Science and Pseudoscience in Ghost Investigations". Skeptical Inquirer (Committee for Skeptical Inquiry) 34 (5): 44–46. 

See also